Mumbai Data Center (DC5)

Mumbai Data Center (DC5)

With 9 service providers, Netmagic's DC5 is ranked #4
in the Mumbai market. In India it ranks #8 amongst
the other 118 operating colocation facilities.

Mumbai DC5 is located at Chandivali, Mumbai and offers all the benefits of a highly connected location, with access to numerous network providers, Internet exchange points and service delivery networks.

This facility also boasts the highest level of disaster protection and recovery in India, managed by a world-class team of professionals.

30,000 m2

Gross Building Size

5,800 M2

Gross Colocation Size

24MW

Total Power

6.00KW

Max Rack Power

Specifications

We bring in decade of experience in building world class datacenters to meet your mission critical hosting requirements.

Facility specifications

  • Building Type: Purpose built datacenter building with 2 basements, GF+7F, floor 1 to 5 dedicated to DC
  • Load Bearing Capacity: 1,500 kgs/sq.mt
  • Datacenter Type: TIER III certified
  • Standard Rack with Front and rear perforated door with a size 600mm × 1000mm × 2100mm (42U)
  • Provision for hosting customizable racks

Power specifications

  • Power Receiving: TATA Power
  • Load Capacity: 24MVA
  • Transformer Capacity: N+2, 12 x 2500 KVA
  • UPS system with N+N redundant configuration
  • Dual Power Sources (PDU) to each rack
  • Battery Back Up: 10 minutes on full load
  • Fuel Storage: 50,000 Ltrs x 4 Nos (underground tanks), 48 hrs on full load
  • Standard Power per Rack: 16 Amp, 32 Amp (Redundant Circuits)
  • Default provision for Ultra-High / High / Medium / Low density racks

Cooling specifications

  • Air-cooling system with N+2 Precision AC management of temperature and humidity
  • N+2 Redundancy
  • Bottom up air supply

Security specifications

  • DC is located in a secure campus
  • Motion based IP CCTV cameras
  • 24x7 on-site physical security present
  • Campus Access: Photo ID required
  • Room Access: Access card and biometric authentication
  • Default mechanical locks on rack front and rear

Fire protection specifications

  • HSSD / VESDA Aspiration System
  • Fire Suppression: Novec1230 Gas
  • Separate zones for each server hall, UPS rooms, battery rooms
  • Novec 1230 gas based fire security system
  • Sprinkler based + portable extinguishers office area protection
  • Addressable fire alarm system

Certifications & Compliance

  • ISO- 27001:2013 (ISMS), ISO-20000-1:2011 (ITSM), ISO-9001:2015 (QMS), ISO 22301:2012 (BCMS), ISO 27017 (Cloud Security), ISO 27018 (Cloud Privacy)
  • PCI-DSS v3.2.1, CISCO CMSP
  • SAP HANA - Operations, SAP - Hosting Operations, SAP - Cloud and Infrastructure Operations
  • CERT-In Empanelment
  • MeitY CSP Empanelment
  • Service Organization Controls (SOC) 1 Type 2 Report
  • Service Organization Control (SOC) 2 Type 2 Report
  • TIA- 942 Tier- 3 for Data Centre

Network & Connection

  • Network: TCL | Bharti Airtel | Reliance Communication | Reliance Jio | Vodafone | TTML | Sify | Microscan | Interwire Mumbai IX
  • Internet connections from 1 up to 10 Gbit/s as an additional service
  • Direct and redundant connection to BCIX and CDN providers
  • Direct connection to disaster-resistant cable tunnel
  • Direct connection to NTT Com's communication service nodes

Amenities & Benefits

  • Customer seating space
  • Meeting rooms
  • Cafeteria
  • Bunker rooms
  • Recreation room

Maintenance and Operations

  • NOC center offering 24x7 support
  • Expert teams comprised of support staff, call analysts and senior technical staff
  • Highly skilled engineers armed with world-class tools, systems, and processes will monitor your networks on a 24x7 basis
  • Single window Customer Portal for access to billing, support tickets, reports and dashboards
  • Well defined escalation matrix for quick responses to incidents available